Article source:

Application
These cables with increased tolerance to torsion application, improved behaviour against abrasion and extended temperature, UV and ozone resistant are specially designed for wind turbines.
Standards
HD 22.12
UL/CSA 22.2
UL 758
Construction
Conductor: Flexible annealed bare copper, class 5 according to IEC/EN 60228.
Insulation: Special cross-linked EI7 rubber for high temperatures (EPDM class 28). Special thermoset EPR for high temperature can be offered upon request.
Sheath: High mechanical performance special cross-linked EM7 rubber (CPE class 42). Special thermoset CPE improved for low temperature behaviour (-40℃) can be offered upon request.
Technical Data
|
Rated Voltage Uo/U (Um) |
600V |
|
Operating Temperatures |
-40℃~+90℃ |
|
Minimum Bending Radius |
fixed: 4×OD; flexing: 6×OD |
|
Torsion Application |
+/-150°/m |
|
Maximum Permissible Tensile Load |
15 N/mm² |
|
Short-circuit Temperature |
250℃ |
|
Flame Retardant |
EN 50265-1/EN 50265-2-1/IEC 60332-1 |
|
Oil Resistant |
Yes |
|
Ozone Resistant |
Yes |
|
UV Resistant |
Yes |
|
Water Resistant |
Yes |
|
Impact Resistant |
Yes |
Dimensions and Weight
|
Construction |
Nominal Overall Diameter |
Nominal Weight |
|
No. of cores×mm² |
mm |
kg/km |
|
1×120(4/0AWG) |
25.5 |
1540 |
|
1×150(250MCM) |
28.8 |
1810 |
|
1×185(350MCM) |
31.4 |
2210 |
|
1×240(450MCM) |
33.8 |
2750 |
|
1×300(550MCM) |
37.7 |
3520 |
|
1×400(750MCM) |
41.4 |
4510 |
|
1×50(1 AWG) |
18.7 |
730 |
|
1×95(3/0 AWG) |
23.0 |
1220 |
|
3×120(4/0 AWG) |
56.0 |
5200 |
|
3×150(250MCM) |
61.5 |
6400 |
|
3×240(450MCM) |
72.0 |
9780 |
|
3×25(4 AWG) |
30.0 |
1420 |
|
3×35(2 AWG) |
35.3 |
1850 |
|
3×50(1 AWG) |
39.8 |
2480 |
|
3×70(2/0 AWG) |
43.8 |
3180 |
|
3×95(3/0 AWG) |
49.0 |
4260 |
|
4G50(1 AWG) |
42.5 |
3150 |
|
4G70(2/0 AWG) |
48.2 |
4240 |
|
4G95(3/0 AWG) |
53.5 |
5480 |
G: with green-yellow earth core